stm32F407使用12MHz晶振,SysTick比实际快了1.5倍,求解

2019-07-20 02:00发布

这里将HSE_VALUE改为12MHz,
#if !defined  (HSE_VALUE)
  #define HSE_VALUE    ((uint32_t)12000000) /*!< Value of the External oscillator in Hz */
#endif /* HSE_VALUE */

/************************* PLL Parameters *************************************/
/* PLL_VCO = (HSE_VALUE or HSI_VALUE / PLL_M) * PLL_N */
#define PLL_M      (HSE_VALUE / 1000000)
#define PLL_N      336

/* SYSCLK = PLL_VCO / PLL_P */
#define PLL_P      2

/* USB OTG FS, SDIO and RNG Clock =  PLL_VCO / PLLQ */
#define PLL_Q      7
/*******************************************************************************
* Function Name  : SysTick_Configuration
* Description    : Configures the SysTick for OS tick.
* Input          : None
* Output         : None
* Return         : None
*******************************************************************************/
void  SysTick_Configuration(void)
{
    RCC_ClocksTypeDef  rcc_clocks;
    rt_uint32_t         cnts;

    RCC_GetClocksFreq(&rcc_clocks);

    cnts = (rt_uint32_t)rcc_clocks.HCLK_Frequency / RT_TICK_PER_SECOND;
    cnts = cnts / 8;

    SysTick_Config(cnts);
    SysTick_CLKSourceConfig(SysTick_CLKSource_HCLK_Div8);
}
实际运行时,rt_thread_delay(RT_TICK_PER_SECOND);函数比实际快1.5倍,即实际延时只有三分之二秒,rt-thread-v3.1.0版本,stm32F407VET6,晶振是12MHz

友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
14条回答
李申瑞
2019-07-20 16:00
s2333 发表于 2019-5-4 09:02
个人建议你可以另开一个定时器,观察定时器时间是否准确,如果准确,那么可能是你的SysTick设置问题,如果 ...

根据您的建议试了一下,定时器和rt_thread_delay一样都快1.5倍,使用之前的程序(在rt_thread_v2.1的版本上)时钟是准的,板子上的晶振12MHz可以确定没有问题,SysTick设置上,应该只用更改HSE_VALUE=12000000吧,原先是25000000,而且调试时SYSTEM_Frequency=168M,HCLK_Frequency=168M,PLCK1_Frequency=42M,PLCK2_Frequency=84M,都是正常的,感觉像是时钟源没选对,选成了内部时钟源HSI=16M,但是不知道在哪里设置

一周热门 更多>