[mw_shl_code=c,true]void TIM2_IRQHandler(void)
{
if (TIM_GetITStatus(TIM2, TIM_IT_Update) != RESET)//判断是否发生TIM2更新中断
{
TIM_Cmd(TIM2,DISABLE); //关掉定时器2
TIM_SetCounter(TIM2, 0);//重新设初值0
if(recenum >= 8)
{
Uart1_rev_flag = 1;//接收完毕一帧,置位标志位,通知主函数调用接收处理函数
USART_ITConfig(USART1, USART_IT_RXNE, DISABLE);//失能串口1接收中断
}
recenum = 0;
GPIO_SetBits(GPIOF,GPIO_Pin_13);//485发送使能
TIM_ClearITPendingBit(TIM2, TIM_IT_Update);//清除TIM2的中断待处理位
TIM_ClearFlag(TIM2, TIM_FLAG_Update);//清除TIM2待处理标志位
}
}
void USART1_IRQHandler(void)
{
if(USART_GetITStatus(USART1,USART_IT_RXNE)!=RESET)//接收中断
{
USART_ClearITPendingBit(USART1,USART_IT_RXNE);//清除USART1中断待处理位RXNE(RXNE=0)
if(Uart1_rev_flag != 1)
{
if(recenum < 12)//接收分8字节数据 和11字节数据
{
ReceBuf[recenum] = USART1->DR;
recenum++;
TIM_Cmd(TIM2, ENABLE);
TIM_SetCounter(TIM2, 0);
TIM_ITConfig(TIM2, TIM_IT_Update, ENABLE);
}
}
}
/*if(USART_GetITStatus(USART1,USART_IT_TXE)!=RESET)
{
USART_ClearITPendingBit(USART1,USART_IT_TXE);//清除USART1中断待处理位RXNE(RXNE=0)
USART_SendData(USART1,ReceBuf[sendnum]);
sendnum++;
if(sendnum == 8)
{
LED4(ON);
sendnum = 0;
USART_ITConfig(USART1,USART_IT_TXE,DISABLE);
//USART_ITConfig(USART1,USART_IT_RXNE,ENABLE);//打开接收中断使能
//GPIO_ResetBits(GPIOF,GPIO_Pin_13);//485使能接收
}
}*/
//溢出-如果发生溢出需要先清空SR的溢出位,再读DR寄存器 则可清除不断入中断的问题
if(USART_GetFlagStatus(USART1,USART_FLAG_ORE)!=RESET)
{
USART_ClearFlag(USART1,USART_FLAG_ORE); //清溢出位
USART_ReceiveData(USART1); //读DR
}
}[/mw_shl_code]
这是我中断函数,为什么我接收到的第一个数据不是设备地址0x01,但是我用串口监控,看到的是01 03 00 00 00 01 84 0A,但是接收之后就不行了
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
---------------------------------
3“触摸屏会主动发出 (假设站号是01) 01 03 00 00 00 01 84 0A,然后你STM32响应回发 01 03 02 00 00 00 B8 44,这样你的STM32中的数据就显示上去的 ”显示到数值输入框?这个框不是为了写入stm32数据吗?怎么又显示stm32 的数据
这个框 可以是可读可写的 这样就是数值输入显示
也可以是只读的 只显示