请问ICD2不能下载调试的问题??????

2020-02-09 09:37发布

下边是连接输出信息:
Auto-connect not enabled - Not connecting (Try enabling auto-connect on the ICD2 settings pages.)
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to target
Target Device dsPIC33FJ128GP710 found, revision = Rev 0x3002
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 ready for next operation
Programming Target...
...Validating configuration fields
...Erasing Part
...Programming Programming Executive
...Verifying Programming Executive
ICD0161: Verify failed (MemType = Test, Address = 0x800080, Expected Val = 0x80011C, Val Read = 0x0)
ICD0275:  Programming failed.
MPLAB ICD 2 ready for next operation
折腾了一上午了也没弄好,换了个芯片还是这样,请了解的朋友多多指教!!
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
14条回答
headwolf_83
2020-02-10 13:02
确实会有一些ICD2,8位可以烧,但对付16位会有问题。看看周围有没有同事也在用,先拿一台过来看看。MCLR只留一个10K上拉,其余电路拆光看看。
换PICKIT3吧。更好用。