本帖最后由 jiaruoge 于 2016-11-1 11:43 编辑
28335无法连接仿真器,复位电路在附件里面:
具体的原因已经找到了:上图为复位电路,S301是拨码开关,GPIO72输出的是周期为2S,占空比为50%的方波,用来改变WDI的电位(如果WDI的电位在1.6S后不变,那么5脚置低,28335复位,否则5脚一直是高电位),3305的5脚接28335的复位脚。第一次烧写程序的时候运行正常,S301合上了,第二次烧写的时候,忘记把S301断开了,导致在往里面烧写程序的时候,一直处于擦除旧程序的进程,因为无法取消,就强行把ccs关闭了,后来再次打开,连接仿真器的时候就出现了这个错误,该怎么解决呢?28335连接上XDS100V3的仿真器之后,测试连接的时候报下面这个错误:
[Start]
Execute the command:
%ccs_base%/common/uscif/dbgjtag -f %boarddatafile% -rv -o -F inform,logfile=yes -S pathlength -S integrity
[Result]
-----[Print the board config pathname(s)]------------------------------------
C:UsersADMINI~1AppDataLocal.TI693494126
0 BrdDat estBoard.dat
-----[Print the reset-command software log-file]-----------------------------
This utility has selected a 100- or 510-class product.
This utility will load the adapter 'jioserdesusbv3.dll'.
The library build date was 'Aug 20 2013'.
The library build time was '22:56:19'.
The library package version is '5.1.232.0'.
The library component version is '35.34.40.0'.
The controller does not use a programmable FPGA.
The controller has a version number of '4' (0x00000004).
The controller has an insertion length of '0' (0x00000000).
This utility will attempt to reset the controller.
This utility has successfully reset the controller.
-----[Print the reset-command hardware log-file]-----------------------------
The scan-path will be reset by toggling the JTAG TRST signal.
The controller is the FTDI FT2232 with USB interface.
The link from controller to target is direct (without cable).
The software is configured for FTDI FT2232 features.
The controller cannot monitor the value on the EMU[0] pin.
The controller cannot monitor the value on the EMU[1] pin.
The controller cannot control the timing on output pins.
The controller cannot control the timing on input pins.
The scan-path link-delay has been set to exactly '0' (0x0000).
An error occurred while hard opening the controller.
-----[An error has occurred and this utility has aborted]--------------------
This error is generated by TI's USCIF driver or utilities.
The value is '-233' (0xffffff17).
The title is 'SC_ERR_PATH_BROKEN'.
The explanation is:
The JTAG IR and DR scan-paths cannot circulate bits, they may be broken.
An attempt to scan the JTAG scan-path has failed.
The target's JTAG scan-path appears to be broken
with a stuck-at-ones or stuck-at-zero fault.
[End]
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
一周热门 更多>