为什么用这种连接符号的原理图,在网络连接的时候会提示错误??
Dangling Connec
tions with a Net Name
P30
Sheet 1 X1600 Y6000
Sheet 1 X6900 Y6100
P32
Sheet 1 X1600 Y5800
Sheet 1 X6900 Y5800
Subnets with Missing Off-Page Reference
P30
Sheet 1 X1800 Y6000 - Pin: U1.5
Sheet 1 X6600 Y6100 - Pin: U2.19
P32
Sheet 1 X1800 Y5800 - Pin: U1.8
Sheet 1 X6600 Y5800 - Pin: U2.22
-
在这一节中:
Adding Connections
When you add connections, they must have start and end points that are electrically meaningful.
Start a connection on either a symbol pin or another connection. End a connection on a symbol
pin, another connection, a bus, an off-page reference, or a ground or power symbol. PADS
Logic prevents you from starting or ending a connection just anywhere in the database unless
you enable Floating Connections.
明确地说了任何一个connection 必须连接到有意义的节点上面,或者管脚,或者off-page connector或者电源,或者另一个connection. PADS logic阻止你随便开始或者结束一个connection, 也就是说 connection 不允许悬空。 但是文档又说了。除非你使能了 floating connections.