Module for Step 'Test for
labview Dev' not Loadable. Failed to load VI 'C:UsersPublicDocumentsNa
tional InstrumentsTestStand 2016 (64-bit)ExamplesCommonLabVIEW Dev Load Test.vi' in the LabVIEW Run-Time Engine version '13.0.1f6'.
LabVIEW: VI is not loadable.
In a built application, this error might occur because the VI being loaded was last compiled for a different OS or with CPU features, such as SSE, that this target does not support. In this case you must rebuild the application for the target OS and make sure SSE compiler settings in the build specifications match the target platform. This error also might occur if the VI is a polymorphic VI, which cannot be loaded in the LabVIEW Run-Time Engine. You must load an instance of the polymorphic VI instead of the polymorphic VI itself.
An error occurred loading VI 'LabVIEW Dev Load Test.vi'. LabVIEW load error code 1: LabVIEW load error code %ld: %p
我的TESTSTAND装的是2016(Runtime engine 没问题),Labview装的是2017,从NI MAX中可以看得到Runtime engine 13.0.1f6 ,15,2017都有的,NI VISA 2017也装了;用Labview单独打开LabVIEW Dev Load Test.vi运行没问题,查看其属性是13.0,所以我觉得Labview中的Runtime没啥问题吧,求大神指教
haha ,没找到他该在的位置,很感谢您的热心,我的问题已经解决了,在ni.com/support 那里找的相关解释,因为我LabVIEW2017用的是32位的,teststand是64位的,后来把TestStand换成2017-32位版就没这个问题了,RTE配置那里自然也就出现了17.0.
一周热门 更多>