[WebMethod]
public DataSet GetLineByID(long id)
{
IndexCommonBasePage basePage = new IndexCommonBasePage();
string json = string.Empty;
var dsPole = new DataSet();
var dtPole = new DataTable();
dtPole.Columns.Add("Name", typeof(string));
dtPole.Columns.Add("PoleTypeValue", typeof(string));
dtPole.Columns.Add("ID", typeof(long));
dtPole.Columns.Add("AngleDirection.Value", typeof(string));
dtPole.Columns.Add("AngleDegree", typeof(decimal));
dtPole.Columns.Add("PoleDistance", typeof(decimal));
dtPole.Columns.Add("SamePoleLoopNum", typeof(int));
dtPole.Columns.Add("SeqNo", typeof(decimal));
dtPole.Columns.Add("VoltageLevelValue", typeof(string));
dtPole.Columns.Add("Line.ID", typeof(long));
dsPole.Tables.Add(dtPole);
Line item1 = basePage.BaseRecordService.GetLineById(id);
IList
collectPole1 = basePage.DeviceService.GetPoles(id);
if (collectPole1 != null && collectPole1.Count > 0)
{
foreach (Spf.Domain.Model.Pole i in collectPole1)
{
Line line = new Line();
var drPole = dtPole.NewRow();
drPole[0] = i.Name;
drPole[1] = i.PoleTypeValue;
drPole[2] = i.ID;
drPole[3] = i.AngleDirection == null ? string.Empty : i.AngleDirection.Value;
drPole[4] = i.AngleDegree;
drPole[5] = i.PoleDistance;
drPole[6] = i.SamePoleLoopNum;
drPole[7] = i.SeqNo;
drPole[8] = i.VoltageLevelValue;
drPole[9] = i.Line == null ? 0 : i.Line.ID;
dtPole.Rows.Add(drPole);
GetPoleByID(i.ID);
}
}
return dsPole;
}
[WebMethod]
public DataSet GetPoleByID(long id)
{
IndexCommonBasePage basePage = new IndexCommonBasePage();
var dsPole = new DataSet();
var dtPole = new DataTable();
dtPole.Columns.Add("Name", typeof(string));
dtPole.Columns.Add("Pole.TypeValue", typeof(string));
dtPole.Columns.Add("ID", typeof(long));
dtPole.Columns.Add("AngleDirection.Value", typeof(string));
dtPole.Columns.Add("AgnleDegree", typeof(decimal));
dtPole.Columns.Add("Pole.PoleDistance", typeof(decimal));
dtPole.Columns.Add("Pole.SamePoleLoopNum", typeof(int));
dtPole.Columns.Add("VoltageLevelValue", typeof(string));
dtPole.Columns.Add("Pole.ID", typeof(long));
dsPole.Tables.Add(dtPole);
Pole pole = basePage.BaseService.GetEntityById(id);
IList lineNew = pole.NewLines;
if (lineNew.Count > 0)
{
foreach (Spf.Domain.Model.Line item in lineNew)
{
var drPole = dtPole.NewRow();
drPole[0] = item.Name;
drPole[1] = item.Pole == null ? string.Empty : item.Pole.TypeValue;
drPole[2] = item.ID;
drPole[3] = item.AngleDirection == null ? string.Empty : item.AngleDirection.Value;
drPole[4] = item.Pole == null ? 0 : item.Pole.AngleDegree;
drPole[5] = item.Pole == null ? 0 : item.Pole.PoleDistance;
drPole[6] = item.Pole == null ? 0 : item.Pole.SamePoleLoopNum;
drPole[7] = item.VoltageLevelValue;
drPole[8] = item.Pole == null ? 0 : item.Pole.ID;
dtPole.Rows.Add(drPole);
GetLineByID(item.ID);
}
}
return dsPole;
}
}
上面我是我在webservice中的源码,我想通过GetLineByID得到GetPoleByID中的数据,并填入GetLineByID的dataset中