DSP

折腾了一天, 我的TMS320C6713 JTAG 终于通了

2019-07-13 17:35发布

总结一下:
1.光盘中的驱动是32位的,  在win7  64bit下,  必须装CSDN 上下在的那个SSD Emulator setup for CCS4.2 by 5.3 m for 64bit.exe 2.  这个驱动没有WIn7 签名认证,  所以必须在WIN7启动时进入禁止强制签名模式,否则这个驱动有感叹号 3.   在connect时, 有可能会出现 以下 几种报错 :   error connecting to the target:
Error 0x80000200/-1073
Fatal Error during: OCS, 
Bad Target Silicon Revision Number
Please check your multi-processor configuration.
The number of devices in the JTAG scan path
must be correct for the silicon revision to be read.
Or, you may have selected the wrong DSP device driver.

------------------------------
Sequence ID: 0
Error Code: -1073
Error Class: 0x80000200
I/O Port = 240


Board Name: C671x SEEDXDS510PLUS Emulator
Cpu Name: TMS320C671x_0


Abort: Close Code Composer Studio.
Retry: Try to connect to the target again.
Cancel: Remain disconnected from the target
Diagnostic: Run diagnostic utility.


--------------------------
rror connecting to the target:
Error 0x80000200/-171
Fatal Error during: OCS, 
This error was generated by TI's USCIF driver.


SC_ERR_REG_DETECT_CTLR <-171>
The wrong controller port value has been used.
A controller cannot be detected even though the
selected port does match the hardware configuration.
The standard 560 ports are 0x0, 0x1, 0x2 and 0x3.
The standard EVM ports are 0x0, 0x1, 0x2 and 0x3.
The standard DSK ports are 0x378, 0x278 and 0x3BC.
The standard 510 ports are 0x240, 0x280, 0x320 and 0x340.


Sequence ID: 0
Error Code: -171
Error Class: 0x80000200
I/O Port = 240


Board Name: C671x SEEDXDS510PLUS Emulator
Cpu Name: TMS320C671x_0


Abort: Close Code Composer Studio.
Retry: Try to connect to the target again.
Cancel: Remain disconnected from the target
Diagnostic: Run diagnostic utility.
-------------------------------------------
Error connecting to the target:
Error 0x80000200/-1070
Fatal Error during: OCS, 
An unknown error prevented the emulator from accessing the processor
in a timely fashion.
It is recommended to RESET EMULATOR.  This will disconnect each 
target from the emulator.  The targets should then be power cycled
or hard reset followed by an emureset and reconnect to each target.




Sequence ID: 0
Error Code: -1070
Error Class: 0x80000200
I/O Port = 240


Board Name: C671x SEEDXDS510PLUS Emulator
Cpu Name: TMS320C671x_0


Abort: Close Code Composer Studio.
Retry: Try to connect to the target again.
Cancel: Remain disconnected from the target
Diagnostic: Run diagnostic utility.
----------------------------------------------------------------------------------------