hpux- hp小型机日常硬件故障处理case(三)

2019-07-13 23:52发布

主机型号:ia64 hp superdome server SD32A 存储型号:XP24000 软件版本:hpux 11.31 + oracle11g  LED显示:attention 红灯 故障现象:主机2块48V电源坏掉 日志显示(操作系统mail日志): From root@superdome Tue Aug 21 21:05:57 EAT 2012
Received: (from root@localhost)
by superdome9000 (8.11.1/8.11.1) id q7LD5vP26317;
Tue, 21 Aug 2012 21:05:57 +0800 (EAT)
Date: Tue, 21 Aug 2012 21:05:57 +0800 (EAT)
Message-Id: <201208211305.q7LD5vP26317@superdome9000>
To: root@superdome9000
From: root@superdome9000
Subject: superdome9000: Event Monitor Notification
Status: RO

>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Tue Aug 21 21:05:57 2012

superdome9000 sent Event Monitor notification information:

/system/events/ipmi_fpl/ipmi_fpl is >= 3.
Its current value is MAJORWARNING(3).



Event data from monitor:

Event Time..........: Tue Aug 21 21:05:57 2012
Severity............: MAJORWARNING
Monitor.............: fpl_em
Event #.............: 655
System..............: superdome9000

Summary:
48 Volt Converter Failed. Data Byte 3 specifies PDCA number.


Description of Error:

A 48 Volt DC Converter powered by the specified PDCA failed on the designated
Bulk Power Supply. The PDCA powering the converter on the BPS that failed can
be identified by the implementation dependent field (data byte 3) of the BPS'
physical location: data byte[3]: 0 for PDCA 0, 1 for PDCA 1.

Probable Cause / Recommended Action:


Cause: The 48 Volt DC Converter powered by the PDCA identified failed in the
named Bulk Power Supply. Action: Contact HP Support personnel to troubleshoot
problem Cause: The PDCA identified has failed. This will be evident by many
BPS_FAIL codes and probably a AC_DELETED code in the Event Log. Action: Contact
HP Support personnel to troubleshoot problem
-


Additional Event Data:
System IP Address...: 10.10.0.1
Event Id............: 0x503387b500000000
Monitor Version.....: A.01.00
Event Class.........: System
Client Configuration File...........:
/var/stm/config/tools/monitor/default_fpl_em.clcfg
Client Configuration File Version...: A.01.00
Qualification criteria met.
Number of events..: 1
Associated OS error log entry id(s):
None
Additional System Data:
System Model Number.............: ia64 hp superdome server SD32A
EMS Version.....................: A.04.10
STM Version.....................: C.46.00
System Serial Number............:
Latest information on this event:
http://docs.hp.com/hpux/content/hardware/ems/fpl_em.htm#655

v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v


IPMI event hex: 0x64800ae900e00000 0x00ffffff0502ff44
Time Stamp: Tue Aug 21 21:21:00 2012
Event keyword: BPS_FAIL_48FLT
Alert level name: Warning
Reporting vers: 1
Data field type: Physical location
Decoded data field: FRU Physical Location: 0x00ffffff0502ff44
FRU Source = 4(power entity)
Source Detail = 4(high voltage DC power)
Cabinet Location = 0


Level 5 (Impl. Dep.)= 5
Slot Number = 2
Reporting entity ID: 0 ( Cab 0 )
Reporting entity Full Name: Power Monitor
IPMI Event ID : 2793 (0xae9)


>---------- End Event Monitoring Service Event Notification ----------<   处理情况: 1.根据日志显示,主机电源出问题 2.打开主机,发现电源出问题 3.更换备件电源(可以支持热插拔,最好是等待下班,业务较少时候,或者晚上),电源显示正常。 4.登陆主机MP管理系统,清除 告警日志。