stm32F407使用12MHz晶振,SysTick比实际快了1.5倍,求解

2019-07-20 02:00发布

这里将HSE_VALUE改为12MHz,
#if !defined  (HSE_VALUE)
  #define HSE_VALUE    ((uint32_t)12000000) /*!< Value of the External oscillator in Hz */
#endif /* HSE_VALUE */

/************************* PLL Parameters *************************************/
/* PLL_VCO = (HSE_VALUE or HSI_VALUE / PLL_M) * PLL_N */
#define PLL_M      (HSE_VALUE / 1000000)
#define PLL_N      336

/* SYSCLK = PLL_VCO / PLL_P */
#define PLL_P      2

/* USB OTG FS, SDIO and RNG Clock =  PLL_VCO / PLLQ */
#define PLL_Q      7
/*******************************************************************************
* Function Name  : SysTick_Configuration
* Description    : Configures the SysTick for OS tick.
* Input          : None
* Output         : None
* Return         : None
*******************************************************************************/
void  SysTick_Configuration(void)
{
    RCC_ClocksTypeDef  rcc_clocks;
    rt_uint32_t         cnts;

    RCC_GetClocksFreq(&rcc_clocks);

    cnts = (rt_uint32_t)rcc_clocks.HCLK_Frequency / RT_TICK_PER_SECOND;
    cnts = cnts / 8;

    SysTick_Config(cnts);
    SysTick_CLKSourceConfig(SysTick_CLKSource_HCLK_Div8);
}
实际运行时,rt_thread_delay(RT_TICK_PER_SECOND);函数比实际快1.5倍,即实际延时只有三分之二秒,rt-thread-v3.1.0版本,stm32F407VET6,晶振是12MHz

友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
该问题目前已经被作者或者管理员关闭, 无法添加新回复
14条回答
Electronic
1楼-- · 2019-07-21 22:24
我没记错的话需要修改两个地方,个人觉得是主时钟应该没问题,应该是你哪个参数还是8M的参数,使初始化SysTick定时器的值不对,你可以看看SysTick的Load寄存器的值是不是所需要的值。我估计是这里配置错了
sheepsleepin414
2楼-- · 2019-07-22 02:07
 精彩回答 2  元偷偷看……