本人新手一枚,在写状态机的时候综合时出现了问题,求助各位大神,代码如下
LIBRARY IEEE ;
USE IEEE.STD_LOGIC_1164.ALL ;
ENTITY control IS
PORT
(
clk : IN STD_LOGIC; -- Standard ports
reset : IN STD_LOGIC; --Recive a signal from the rest key
start_pause : IN STD_LOGIC; --Recive a signal from the start or pause key
zero : IN STD_LOGIC; --Recive the zero signal from the counter
cnt_en : OUT STD_LOGIC; --Give out a singal to run the counter
cnt_reset : OUT STD_LOGIC; --Give out a singal to reset the counter
alarm_en : OUT STD_LOGIC --Give out a signal to the alarm clock
);
END ;
ARCHITECTURE bhv of control IS
TYPE states IS (s0, s1, s2) ;
SIGNAL cs, next_state: states :=s0 ;
BEGIN
REG: PROCESS (clk,reset) BEGIN
IF reset='0'
THEN cs <= s0;
cnt_reset <='1';--?
ELSIF clk'EVENT AND clk='1'
THEN cs <= next_state;
cnt_reset <='0'; --?
END IF;
END PROCESS REG;
COM: PROCESS(cs, start_pause) BEGIN
CASE cs IS
WHEN s0 => cnt_en<='0';
IF (start_pause='1') AND (zero <='0' )
THEN next_state <= s1;
ELSE next_state <= s0;
END IF;
WHEN s1 => cnt_en<='1';
IF zero='1'
THEN next_state <= s0;
ELSIF (start_pause='1')
THEN next_state <= s2;
ELSE next_state <= s1;
END IF;
WHEN s2 => cnt_en<='0';
IF (start_pause='1')
THEN next_state <= s1;
ELSE next_state <= s2;
END IF;
WHEN OTHERS => next_state <= s0;
END CASE;
END PROCESS COM;
alarm_en <=zero;
END bhv;
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。