DS61154A-page 34-15
CiCON寄存器
bit 23-21 OPMOD<2:0>: Operation Mode Status bits
111 = Module is in Listen All Messages mode
110 = Reserved
101 = Reserved
100 = Module is in Configuration mode
011 = Module is in Listen Only mode
010 = Module is in Loopback mode
001 = Module is in Disable mode
000 = Module is in Normal Operation mode
bit 15 ON: CAN On bit
1 = CAN module is enabled
0 = CAN module is disabled
这两个Disable有什么区别?谢谢
一周热门 更多>