请问ICD2不能下载调试的问题??????

2020-02-09 09:37发布

下边是连接输出信息:
Auto-connect not enabled - Not connecting (Try enabling auto-connect on the ICD2 settings pages.)
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to target
Target Device dsPIC33FJ128GP710 found, revision = Rev 0x3002
...Reading ICD Product ID
Running ICD Self Test
...Passed
MPLAB ICD 2 ready for next operation
Programming Target...
...Validating configuration fields
...Erasing Part
...Programming Programming Executive
...Verifying Programming Executive
ICD0161: Verify failed (MemType = Test, Address = 0x800080, Expected Val = 0x80011C, Val Read = 0x0)
ICD0275:  Programming failed.
MPLAB ICD 2 ready for next operation
折腾了一上午了也没弄好,换了个芯片还是这样,请了解的朋友多多指教!!
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
该问题目前已经被作者或者管理员关闭, 无法添加新回复
13条回答
lvgaopan
1楼-- · 2020-02-09 12:32
 精彩回答 2  元偷偷看……
longfeixue
2楼-- · 2020-02-09 14:13
谢谢楼上,按你说的方法试验了,但还是出现
ICD0161: Verify failed (MemType = Test, Address = 0x800080, Expected Val = 0x80011C, Val Read = 0x0)
这个错误,不知道怎么回事。
在点连接的过程中,也会时不时会出现这样的情况
Connecting to MPLAB ICD 2
...Connected
Setting Vdd source to target
Target Device dsPIC33FJ128GP710 found, revision = Rev 0x0
...Reading ICD Product ID
Running ICD Self Test
...Passed


revision = Rev 0x0 这一行好像也不正常吧
dianxinwuban
3楼-- · 2020-02-09 16:14
0161是烧写电流不足引起的,看下你的电源模块,最好能有外部电源
longfeixue
4楼-- · 2020-02-09 17:19
谢谢楼上,电源供电是用外部单独供电的,5伏,再转成3.3伏。应该没有问题的
h32dong809
5楼-- · 2020-02-09 21:58
芯片坏了也有可能,我以前遇到过芯片坏的情况,怎么下程序也下不进去。
longfeixue
6楼-- · 2020-02-10 00:10