STM32f103 四通道做ADC采样,采样结果异常

2019-07-14 16:59发布

使用STM32做ADC电流采样,4通道,发现当只有一个通道输入电流和四个通道都有电流输入的时候,采样结果会有差异。比如通道1输入3mA电流,其它通道都输入0mA,这时候1通道采样值为2.975mA,当1通道输入仍为3mA,其它通道都输入20mA,这时候的1通道采样值为2.896mA.检测过运放输出端的电压在两种情况下都没有发生改变,采样值却发生了改变。
有没有哪位大神解决过这样的问题?

驱动代码如下,理论上驱动代码应该不会有问题的
ADC_InitTypeDef     ADC_InitStructure;
   GPIO_InitTypeDef    GPIO_InitStructure;
   
   ADC_DeInit(ADC1);                                                             //ADC1 DeInit

   RCC_APB2PeriphClockCmd(RCC_APB2Periph_ADC1 | RCC_APB2Periph_GPIOC, ENABLE);   //ADC1 Periph and GPIOC Periph clock enable

   GPIO_InitStructure.GPIO_Pin = GPIO_Pin_0 | GPIO_Pin_1 | GPIO_Pin_2 | GPIO_Pin_3;//Configure ADC Channel 10-13 as analog input
   GPIO_InitStructure.GPIO_Mode = GPIO_Mode_AIN;
   GPIO_Init(GPIOC, &GPIO_InitStructure);
   
   /* ADC1 configuration ------------------------------------------------------*/
   ADC_InitStructure.ADC_Mode = ADC_Mode_Independent;
   ADC_InitStructure.ADC_ScanConvMode = ENABLE;
   ADC_InitStructure.ADC_ContinuousConvMode = ENABLE;
   ADC_InitStructure.ADC_ExternalTrigConv = ADC_ExternalTrigConv_None;
   ADC_InitStructure.ADC_DataAlign = ADC_DataAlign_Right;
   ADC_InitStructure.ADC_NbrOfChannel = 4;
   ADC_Init(ADC1, &ADC_InitStructure);

   ADC_RegularChannelConfig(ADC1, ADC_Channel_10, 1, ADC_SampleTime_55Cycles5);
   ADC_RegularChannelConfig(ADC1, ADC_Channel_11, 2, ADC_SampleTime_55Cycles5);
   ADC_RegularChannelConfig(ADC1, ADC_Channel_12, 3, ADC_SampleTime_55Cycles5);
   ADC_RegularChannelConfig(ADC1, ADC_Channel_13, 4, ADC_SampleTime_55Cycles5);

   ADC_DMACmd(ADC1, ENABLE);                                                     //Enable ADC1 DMA
   
   ADC_Cmd(ADC1, ENABLE);                                                        // Enable ADC1

   ADC_ResetCalibration(ADC1);                                                   //Enable ADC1 reset calibration register
   
   while(ADC_GetResetCalibrationStatus(ADC1));                                   //Check the end of ADC1 reset calibration register

   ADC_StartCalibration(ADC1);                                                   //Start ADC1 calibration

   while(ADC_GetCalibrationStatus(ADC1));                                        //Check the end of ADC1 calibration      
      
   ADC_SoftwareStartConvCmd(ADC1, ENABLE);                                       //Start ADC1 Software Conversion


DMA_InitTypeDef   DMA_InitStructure;
   /* DMA1 clock enable */
   RCC_AHBPeriphClockCmd(RCC_AHBPeriph_DMA1 , ENABLE);
   
   /* DMA1 Channel1 Config */
   DMA_DeInit(DMA1_Channel1);
   DMA_InitStructure.DMA_PeripheralBaseAddr = (uint32_t)ADC1_DR_Address;         //ADC1->DR
   DMA_InitStructure.DMA_MemoryBaseAddr = (uint32_t)ConvData_Tab;
   DMA_InitStructure.DMA_DIR = DMA_DIR_PeripheralSRC;
   DMA_InitStructure.DMA_BufferSize = ADC_TIMES_ALL ;
   DMA_InitStructure.DMA_PeripheralInc = DMA_PeripheralInc_Disable;
   DMA_InitStructure.DMA_MemoryInc = DMA_MemoryInc_Enable;
   DMA_InitStructure.DMA_PeripheralDataSize = DMA_PeripheralDataSize_HalfWord;
   DMA_InitStructure.DMA_MemoryDataSize = DMA_MemoryDataSize_HalfWord;
   DMA_InitStructure.DMA_Mode = DMA_Mode_Circular;
   DMA_InitStructure.DMA_Priority = DMA_Priority_High;
   DMA_InitStructure.DMA_M2M = DMA_M2M_Disable;
   DMA_Init(DMA1_Channel1, &DMA_InitStructure);
   /* DMA1 Channel1 enable */
   DMA_Cmd(DMA1_Channel1, ENABLE);

友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
该问题目前已经被作者或者管理员关闭, 无法添加新回复
2条回答
asgfafa
1楼-- · 2019-07-15 01:57
 精彩回答 2  元偷偷看……
qiangqzuo
2楼-- · 2019-07-15 05:02
谢谢兄弟  参考电压用的参考电压芯片  测试了  没有变化了   用台表测试的        采集方式是循环采集 和 第几次才没有关系   采样结果都不变的