TI提供的免费CCS v4兼容win7吗?

2019-03-24 09:12发布

       我搞了个MSP430 launch pad开发板,到TI的网站下了他们提供的免费SSC v4,安装后,打开的时候到设置work bench后就不动了,始终无法打开程序,是否是不兼容win7的原因,因为是正版系统,舍不得换成win XP,希望高手指导,提供个解决方法。谢谢! 此帖出自小平头技术问答
友情提示: 此问题已得到解决,问题已经关闭,关闭后问题禁止继续编辑,回答。
该问题目前已经被作者或者管理员关闭, 无法添加新回复
13条回答
mawenwei
1楼-- · 2019-03-24 19:38
< CCSv4
By default, Microsoft Windows Vista and Windows 7 do not allow user level accounts to write files in the "Program Files" directory. This can prevent CCS from starting when installed in the "Program Files" or "Program Files (x86)" directory, because CCS stores configuration data by default in its install directory. Either of the following workarounds can be used to avoid this problem:

Install CCS outside the "Program Files" or "Program Files (x86)" directory
Instruct CCS to store configuration data outside the "Program Files" or "Program Files (x86)" directory using the -configuration command line argument. The problem will not occur when running CCS as the Administrator user, but this is not recommended because it compromises the Windows Vista security model
fengkb
2楼-- · 2019-03-24 22:37
 精彩回答 2  元偷偷看……
David_Lee
3楼-- · 2019-03-24 22:49

原帖由 mawenwei 于 2010-12-17 10:01 发表 CCSv4 By default, Microsoft Windows Vista and Windows 7 do not allow user level accounts to write files in the "Program Files" directory. This can prevent CCS from starting when installed in the "Pr ...

 

呵呵,我的安装目录是自定义d:/programs,工程路径在e:/documents,没有给CCS4设置管理员权限,正常使用。楼主可以按照楼上的设置下看看行否。我的操作系统是win7 32bit ultimate。

建议:开发msp430还是用IAR好点,缘由见下帖:

IAR5.10 VS CCS4.1 (430)

http://bbs.eeworld.com.cn/thread-204191-1-1.html

David_Lee
4楼-- · 2019-03-25 02:06

原帖由 fengkb 于 2010-12-17 10:11 发表 我的系统装在C盘,ccsv4装是E盘,workbench也在E盘,但问题依旧啊

 

试试下面两个选项,看看行不,右击CCS4快捷方式图标:

win7.jpg

fengkb
5楼-- · 2019-03-25 05:50
 精彩回答 2  元偷偷看……
fengkb
6楼-- · 2019-03-25 11:23
路径没中文就行,现在明白了,以后工程软件都不带中文路径。

一周热门 更多>

相关问题